Customization: | Available |
---|---|
After-sales Service: | Tracking Services, Technical Guidance |
Warranty: | 3year |
Still deciding? Get samples of US$ 100/kg
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Metallic zinc coating
When applying our advanced metallic zinc spray, the average mass of zinc per unit area is ensured to be no less than 130g/m², adhering to strict quality standards.Additionally, a local minimum of 110g/m² is maintained, with options for customization based on customer specifications.
Bitumen coating
Our bitumen coating features a mean thickness of no less than 70 μm, with a local minimum thickness of no less than 50 μm. Custom thicknesses are also available to meet specific customer needs.
Alternative coating
Process and Testing Procedures:
1. Induction Furnace and Treated Metal: Involves chemical analysis of raw materials, spheroidizing, and verifying nodularity.
2. Casting: Includes visual inspection and weight verification to ensure quality.
3. Heat Treatment: Examines the microstructure to guarantee material integrity.
4. Hydrostatic Test: Conducts pressure testing for durability.
5. Dimensional Checks: Measures pipe length, joint OD, wall thickness, and overall appearance.
6. Zinc Spraying: Performs thickness testing to ensure proper coating.
7. Lining and Coating: Involves 100% visual inspection and random thickness testing.
8. Marking and Packing: Ensures a 100% visual check for quality.
Project Case